RFQ template

DEXA Scanner RFQ Template

WHO-aligned DEXA Scanner RFQ template covering required specifications, optional features, accessories, compliance, warranty, training, service, acceptance, maintenance, and lifecycle cost.

Overview

DEXA scanner procurement for bone mineral density, T-score/Z-score reporting, positioning, phantom QA, dose, and service.

Evaluate precision, reproducibility, supported examinations, patient positioning, QA and calibration, analysis software, reference data, reporting integration, and local service—not only scan speed.

Separate mandatory clinical applications from optional software packages. Require site-planning documents, high-cost component warranty, DICOM testing, and acceptance image-quality baseline before award.

WHO procurement and technical-specification principles are used as the baseline: intended use, level of care, functional requirements, utilities, accessories, consumables, spare parts, environmental requirements, training, warranty, maintenance, documentation, standards, regulatory evidence, and decommissioning cautions should be addressed where relevant.

Required Specifications

  • State exact intended use for dexa scanner, clinical location, workload, user group, required patient/application range where applicable, and level of care.
  • Specify fan- or pencil-beam geometry, detector and scan field, supported sites and patient limits, precision and calibration workflow, body-composition capability if required, analysis software, reference databases, dose reporting, and DICOM/report export.
  • Image-chain configuration, clinical application package, dose or safety controls where relevant, workstation/reporting workflow, DICOM/PACS/RIS connectivity, cybersecurity, and site planning requirements should be specified.
  • High-cost components such as tube, detector, probe, coil, workstation, injector head, chiller, software licenses, and service tools should have clear warranty and replacement pricing.
  • Clinical use area, workload, image acquisition configuration, reconstruction/display workflow, DICOM send/storage, modality worklist where required, cybersecurity update policy, and user access controls.
  • Room readiness requirements including power, HVAC, radiation protection or safety zoning where applicable, network, equipment clearances, delivery path, and acceptance image-quality baseline.
  • Service evidence covering PM frequency, calibration or QA tools, critical spare parts, local engineer response, downtime escalation, and software support.
  • Name, category, and coding: generic name, specific type or variation, local naming/coding where available, and keywords linked to service area.
  • Purpose of use: clinical or operational purpose, level of care, clinical department/ward, user group, and overview of functional requirements.
  • Technical characteristics: critical measured or delivered parameters, ranges, displayed parameters, user-adjustable settings, alarms, compatibility, and interoperability.
  • Physical and utility requirements: dimensions/mobility, electrical supply, battery, water, gas, drain, network, environmental operating/storage limits, humidity, dust, and transport/storage conditions.

RFQ wording examples

Use these examples to convert vague tender wording into measurable vendor responses. Adapt final clauses to the exact model, hospital workload, and local procurement rules.

Mandatory compliance

Weak wording

Equipment should be high quality and latest model.

Stronger RFQ clause

Bidder shall provide a clause-by-clause compliance matrix with comply, partially comply, not comply, or optional; each response shall include documentary evidence and cost impact.

Vendor evidence: Official datasheet, user manual extract, compliance matrix, itemized offer, and deviation list.

Evaluation note: Score measurable compliance and evidence. Do not score unsupported claims, brochure adjectives, or brand preference.

Lifecycle cost

Weak wording

Vendor should provide good service after warranty.

Stronger RFQ clause

Bidder shall submit five-year lifecycle cost including PM kits, consumables, major spare parts, batteries/sensors/probes where applicable, labor/travel, software support, and post-warranty rates.

Vendor evidence: Lifecycle price schedule, PM checklist, spare-parts list, service report sample, and escalation contacts.

Evaluation note: Compare total ownership cost and downtime risk, not purchase price alone.

Optional Specifications

  • Advanced clinical applications, dose analytics, additional workstations, automated reporting/export tools, remote support, or uptime package where clinically justified.
  • Additional detectors, probes, coils, accessories, software licenses, or room integration items priced separately.

Accessories

  • Include calibration/QA phantom, positioning blocks and straps, table pad, workstation and printer/export, body-composition or orthopedic applications if required, DICOM license, and radiation-safety accessories.
  • Price QA phantoms, positioning aids, probes/coils/detectors where applicable, injector accessories, software licenses, workstations, UPS/chiller items, DICOM licenses, and startup consumables.
  • Patient positioning aids, workstation/licenses, DICOM/network accessories, QA phantoms or test tools where applicable, warning/signage items, and required startup consumables.
  • Integration cables, storage/export accessories, operator furniture, UPS if justified by hospital policy, and cleaning-compatible accessories.

Compliance Requirements

  • The bidder shall provide a clause-by-clause compliance matrix with documentary evidence for each mandatory and scored requirement.
  • The bidder shall submit an itemized scope of supply, including main equipment, accessories, consumables, software/licenses, installation, commissioning, training, warranty, PM, spare parts, and exclusions.
  • The bidder shall provide lifecycle cost information for at least five years, including consumables, PM kits, major spare parts, software support, labor/travel, post-warranty rates, and expected replacement items.
  • The bidder shall provide an acceptance and handover plan covering configuration verification, safety/performance inspection, user training, biomedical handover, inventory data, manuals, warranty certificate, PM schedule, and service contacts.
  • The bidder shall identify the generic device name, specific type or variation, intended level of use, clinical department, and functional purpose so the Hospital Administration/Procurement/Biomedical Dept can confirm the offered device matches the actual service need.
  • The bidder shall list utility requirements, environmental operating/storage limits, accessories, consumables, spare parts, packaging/labelling requirements, applicable standards, regulatory approval/certification, and decommissioning/disposal cautions.
  • Bidder must provide documents for the exact offered model, supplied configuration, software version, accessories, and country-specific supply scope.
  • Bidder must identify applicable standards, approvals, certificates, local installation requirements, safety documentation, and any limitations of the supplied evidence.
  • The hospital shall verify local regulatory, accreditation, radiation, electrical, infection-control, and import requirements before award where applicable.

Warranty Requirements

  • State warranty duration and start trigger: delivery, installation, commissioning, or final acceptance.
  • Separate warranty for main unit, accessories, batteries, sensors, probes, software, consumables, installation workmanship, and third-party components where applicable.
  • Disclose exclusions for consumables, user damage, cleaning-fluid damage, utility problems, software upgrades, travel, labor, preventive maintenance, calibration, and accidental damage.
  • Provide post-warranty service contract pricing and spare-parts availability commitment for at least five years where possible.

Training Requirements

  • Provide end-user training before clinical handover using the hospital's actual workflow and supplied accessories.
  • Provide biomedical engineering or facilities training covering daily checks, first-line troubleshooting, PM expectations, documentation, escalation, and safety cautions.
  • Provide attendance sheets, training materials, competency checklist where relevant, and refresher-training pricing.

Service Requirements

  • Biomedical should review QA/phantom requirements, calibration, service access, error logs, software versions, high-cost component warranty, remote service, and downtime escalation.
  • PM should include image quality QA, safety checks, calibration, software/log review, cleaning, mechanical movement checks, cooling/HVAC review, DICOM test, and baseline performance documentation.
  • DEXA TCO includes detector/tube service, calibration phantom and QA, analysis software and database updates, workstation support, room radiation compliance, positioning accessories, and downtime affecting osteoporosis services.
  • TCO includes high-cost components, room works, power/HVAC, QA tools, software licenses, service contract, tube/probe/coil/detector risk, downtime, upgrades, and PACS storage.
  • Request five-year pricing for high-cost components, software support, boards, detectors/image-chain items, accessories, PM kits, labor, travel, and post-warranty service.
  • Clarify exclusions linked to power, HVAC, shielding, network, third-party integration, operator misuse, software upgrades, and consumables.
  • Acceptance shall create the inventory baseline: asset identification, serial numbers, software version, accessories, warranty dates, location, risk/criticality, PM interval, and service contact path.
  • Maintenance planning shall distinguish performance inspection, safety inspection, preventive maintenance, and corrective maintenance rather than treating all service activity as one generic visit.
  • The vendor shall provide PM procedures, required test equipment, spare-parts recommendations, service report format, escalation process, and training needed for hospital first-line checks.
  • Service records shall be usable for audit and first-year review: fault history, parts used, measured values where applicable, open risks, corrective action, and next due date.
  • Maintenance documentation shall state user-care tasks, cleaning/disinfection method, calibration or testing equipment, advanced maintenance tasks, software/hardware upgrade path, and post-warranty spare-parts availability.
  • Vendor must provide PM frequency, service report format, required test equipment, calibration requirements, critical spare-parts list, emergency response time, and escalation contacts.
  • Vendor must submit a five-year lifecycle price schedule for consumables, accessories, PM kits, batteries/sensors/high-wear parts where applicable, software, labor, travel, and post-warranty support.

RFQ files